Report a bug
- In Revit, click QuickBADS → Report Bug, then Open the report folder.
- Email support@quickbads.com with:
- what you did and what you expected to happen,
- a screenshot of the plan,
- the files
last-report.txt(the last Place BADS) andlast-run.txt(the last update) from that folder, - your Revit version.
These two files hold level and apartment names from your model, but no drawings. Nothing is sent unless you send it. We never need your Revit file; if a model would help, we’ll ask and you decide.
Contact
Questions, feedback or help setting up a project: support@quickbads.com.Known limits
Revit and Windows versions
Revit and Windows versions
QuickBADS runs on Revit 2027 on Windows. Earlier Revit versions will follow.
Linked models
Linked models
Walls, doors and furniture in linked models are ignored. Model the apartments in the file you check.
Two plans of the same level
Two plans of the same level
Check one plan per level. Placing BADS on a second plan of the same level (for example a sheet plan) removes the fills from the first one.
Ground floor and gardens
Ground floor and gardens
After ticking BADS Ground Floor on a level, click Place BADS again; ticking alone doesn’t trigger Auto Update. Ground-floor gardens can’t be checked yet and show ?.
Balconies
Balconies
A balcony is measured inside Revit Railings only. A balustrade modelled as a wall or generic model isn’t treated as the handrail.
Storage that looks like an appliance
Storage that looks like an appliance
A cupboard whose type name says “fridge” is read as a fridge. Set its Mark to
P to count it as storage.View templates
View templates
If a plan’s view template controls Filters, QuickBADS can’t add its view filters to that plan. Add them to the template yourself.
Ceiling height
Ceiling height
QuickBADS assumes a 2.7 m ceiling height.